Multi-Object Spectrograph Instruments

Click on the Instrument names to visit the Instrument web pages or click here to return to the Main Instrument Summary Page.

Multi-Object Spectrographs
  CAFOS EFOSC-2 DOLORES AAOmega/2dF LIRIS AF2/WYFFOS
Year of commissioning 1997   2000   2003 1994
Location Spain La Silla La Palma Australia La Palma La Palma
Telescope Name CAHA 2.2 NTT TNG AAT WHT WHT
Telescope Size 2.2 3.5 3.5 3.92 4.2 4.2
Operated by CAHA ESO INAF AAO STFC STFC
Type Multi-slit Multi-slit/grism Multi-slit Multi-fibre Multi-slit Multi-fibre
Accessible wavelength range 0.3-1.1 0.3-1.1 0.3-1.0 0.36-0.9 0.8-2.5 0.3-1.0
Accessible field ( slit length)         4'x4' arcmin 40'arcmin diam
Resolving power(s) 600-3000 1500-5000 500-6000 1300-10000 ~700-2500 100-7500
Unvignetted array dimensions (pixels)           2x2kx4k
Detector pixel size (actual)         18.5 µm 13.5 µm
Detector pixel size, on sky, across dispersion         0.25 arcsec  
Detector pixel size, on sky, along dispersion            
Dispersion (nm/pix)           0.017 to 0.29
No of cross-dispersed orders (echelles only)           from 3 to 7
Spectropolarimetry         No No
Cross Dispersed?         No optional
FP?         No No